SCAN 1004 VE
44Seiten

{{requestButtons}}

Katalogauszüge

SCAN 1004 VE - 1

UK - ASSEMBLY AND INSTRUCTIONS MANUAL ASSEMBLY AND INSTRUCTION MANUAL SCAN 1003 /1004

Katalog auf Seite 1 öffnen
SCAN 1004 VE - 2

CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions. Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.

Katalog auf Seite 2 öffnen
SCAN 1004 VE - 3

Installation Safety CO monitor Technical data and dimensions Tools needed for mounting of the insert Loose parts Additional accessories Load-bearing foundation Floor plate Existing chimney and pre-fabricated element chimney Connection between built-in stove and steel chimney Internal installation in non-flammable material Distance to furniture Safety distance Building into flammable material with fire wall 4 Dimension sketch Scan 1003 4 Dimension sketch Scan 1004 10 Fitting the flue connection piece 10 Closed combustion system 11 Mounting of external air supply 11 Fitting without the...

Katalog auf Seite 3 öffnen
SCAN 1004 VE - 4

TECHNICAL DATA INSTALLATION ¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regulations as well as the information provided in this Assembly and Instructions Manual ¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning ¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional...

Katalog auf Seite 4 öffnen
SCAN 1004 VE - 5

Steel plate Galvanised sheet Ceramic stone/vermiculite Chamotte Robax glass Surface treatment Max. wood length Scan 1003 Max. wood length Scan 1004 * Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refuelling. Scan 1003-1004 is produced in accordance with type approval for the product, which also covers the product's Assembly and Instruction Manual. The Declaration of Performance (DoP) is available from www.scan-stoves.com Weight Scan 1003 (Vermiculite) Weight Scan 1004...

Katalog auf Seite 5 öffnen
SCAN 1004 VE - 6

DIMENSION SKETCH SCAN 1003 Rear outlet Centre external air supply, rear side Centre of external air supply, bottom

Katalog auf Seite 6 öffnen
SCAN 1004 VE - 7

A Top outlet B Rear outlet C Centre external air supply, rear side D Centre of external air supply, bottom

Katalog auf Seite 7 öffnen
SCAN 1004 VE - 8

TYPE PLATE All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials. The type plate (Vermiculite) is located on top of the stove. The type plate for UK must be stuck on top of the existing type plate. Please do not cover the product registration number. Type plate Scan 1003 for UK Type plate Scan 1003 (Vermiculite)

Katalog auf Seite 8 öffnen
SCAN 1004 VE - 9

TYPE PLATE Type plate Scan 1004 for UK Type plate Scan 1004 (Vermiculite) PRODUCT REGISTRATIONUMBER All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S. Product registration number Type plate Product registration number

Katalog auf Seite 9 öffnen
SCAN 1004 VE - 10

■ Spirit level ■ Cutting nippers ■ Cross tip screwdriver ■ Flat head screwdriver ■ 010 wall drill ■ Open-end spanner The trim is packed separately. In the insert's combustion chamber you will find the following loose parts: 8 x 3 mm black self-adhesive gasket (2 m) (0100 mm sleeve, connecting piece and cassette) 4 x torx screws M6 x 50 (for fastening the cassette) 2 x screws M5x6 mm (Only used in Norway) ■ Burn chamber plates (side and rear) ■ Bricks for the bottom of the burn chamber ■ Bag containing loose parts: 4 x self-tapping screws 4.2 x 6.5 mm (for fastening the sleeve 0100 mm) 4 x...

Katalog auf Seite 10 öffnen
SCAN 1004 VE - 11

FLOOR PLATE If you are placing the stove on a flammable floor, you must comply with the national and local regulations on the size of any non-flammable subsurface required to cover the floor around the stove. Your local Scan dealer can advise you on regulations concerning protection of flammable materials in the vicinity of your stove. The floor plate’s function is to protect the floor and flammable material against any sparks that may occur. CONVECTION AIR (BY BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL) The covering must contain holes for convection air. Convection means that there is...

Katalog auf Seite 11 öffnen
SCAN 1004 VE - 12

TRIMS AND DOORS Trims and doors are fitted when the surfaces of the surround have been treated. GASKET Gasket 0,75 m is mounted on the inside of the cassette as shown. DISTANCE TO FURNITURE Distance to furniture from glass: 1500 mm. You should however assess whether furniture or other items might become excessively dry due to being too close to the stove. The stove is NOT to be built into flammable materials without the use of a fire wall! SAFETY DISTANCE European, national and local regulations concerning safety distances for wood-burning stoves and flue pipes must be complied with. Krog...

Katalog auf Seite 12 öffnen
SCAN 1004 VE - 13

BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL Installation with an un-insulated elbow pipe Flammable material Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick or other material with corresponding fireproof and insulating abilities Flammable materials Chimney All distances are in mm. All distances are minimum distances 91005029 * Applies for allTG.NR: installations DATO: Krog Iversen & Co A/S DK-5492 Vissenbjerg© Floor plate These cover plates must be removed when installing into flammable material protected by insulation Ceiling Lille glasgulvplade convection opening MATERIALE:...

Katalog auf Seite 13 öffnen
SCAN 1004 VE - 14

BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL Installation with an insulated, vertical flue pipe - structure/surround to ceiling Cavities are not to be filled out with insulation material! (Ceramic stone) (Vermiculite) Upper convection opening Isoleret røgrør Lower convection opening Krog Iversen & Co A/S DK-5492 Vissenbjerg© Tighten the space, for example with a glass-gasket The distance to fire wall (brick) depends on the use of an insulated flue pipe all the way down to the insert NAVN: Konstruktion/omramning mod loft VÆGT: N/A Møbleringsafstand: 800 mm. Flammable materiale material...

Katalog auf Seite 14 öffnen

Alle Kataloge und technischen Broschüren von Scan A/S

  1. SCAN 1003 VE

    44 Seiten

  2. SCAN 68-10

    44 Seiten

  3. SCAN 67 1300

    36 Seiten

  4. SCAN 66-2

    40 Seiten

  5. SCAN 66-1 WALL

    40 Seiten

  6. SCAN 65-1

    36 Seiten

  7. SCAN 5005 FRL

    36 Seiten

  8. SCAN 5003 S FR

    40 Seiten

  9. SCAN 5004 FL

    44 Seiten

  10. SCAN 5003 FL

    36 Seiten

  11. SCAN 1006 CS

    3 Seiten

  12. SCAN 41-1

    32 Seiten

  13. SCAN 1003 CS

    44 Seiten